Semiconductor pixel radiation detector systems have recently made significant progress achieving excellent spatial resolution, high sensitivity, wide dynamic range and low noise. The hybrid silicon pixel device ofMedipix type developed at CERN was originally designed for position sensitive single X-ray photon detection. We have adapted this device to a position sensitive detector ofslow neutrons by covering the detector surface with a 6LiF neutron converter. Neutrons are converted to tritons and alpha particles which are subsequently detected by the silicon pixel detector. The basic parameters ofsuch a pixel neutron sensitive device were investigated using thermal neutron beams. Tests for neutron imaging applications and comparison with currently used devices for neutron radiography (CCD camera with scintillator, imaging plates) were performed. The aim of this article is to demonstrate the exceptional good spatial resolution for neutrons (up to 8.5 lp/mm in the case of Medipix-2 option), reasonable neutron detection efficiency with very low sensitivity to background gamma radiation, low noise, perfect linearity and wide dynamic range. Results and future prospects are presented in this article.
Projekty


Příklad citace článku:
J. Uher, T. Holý, J. Jakůbek, E. Lehmann, S. Pospíšil, J. Vacík, "Performance of Slow Neutron Pixel Detector", NIM A Vol. 542, pages 283-287 (2005)

Hledat
Události

IEEE NSS/MIC/RTSD
Seoul
27 Oct - 2 Nov 2013

15thIWORID
Paris
23-27 June 2013

NSS MIC IEEE Conference
Anaheim, USA
29 Oct - 3 Nov 2012

Int. Workshop on Radiation Imaging Detectors
1-5 July 2012

Program oslav 10. výročí založení ÚTEF
4-6. 6. 2012

Pozice pro mladé výzkumné pracovníky

Příležitostní razítko k 10. výročí ÚTEF
Na Hrádku 2, Praha 2
30.4, 2-4.5 2012

Collaboration Meeting NEMO/SuperNEMO
Prague, Czech Republic
27.2.-1.3. 2012

Vzpomínkové setkání k připomenutí životní cesty RNDr. Františka Lehara, DrSc.
Refektář Benediktinského opatství v Emauzích, Praha 2
8. února 2012

Zemřel František Lehar
Lyon, Francie
23.11.2011

Vše...
10th Anniversary of IEAP