IEAP - Institute of Experimental and Applied Physics CTU - Czech Technical University in Prague
Česky English
IEAP - Institute of Experimental and Applied Physics CTU - Czech Technical University in Prague
CTU - Czech Technical University in Prague
Partial tasks  > X-ray absorption and phase sensitive radiography and tomography
X-ray absorption and phase sensitive radiography and tomography


Usage of pixel detectors of Medipix family for Developed methodology is applied in the field of:



Responsible person

Co-workers

Grants:
Number Name Agency
LC06041 Research center "Fabrication, modification and characterization of materials by energetic radiation" MŠMT
1P04LA211 Collaboration Czech Republic with CERN MŠMT
MSM 6840770040 Research Program 40: Usage of radionuclides and ionizing radiation. MŠMT


Articles in Conference Proceedings
(30)
Text format
Year

Ocenění Name Author Scientific journal OceněníYear
Application of High-resolution X-Ray Radiography for Monitoring the Penetration Depth of Consolidants in Natural Building Stones Krejčí F. ; Jakůbek J. ; Slavíková M.; Kotlík P. Engineering Mechanics Conference proceedings, Svratka, Czech Rep., Paper #312, pp. 733–739 2012
Detection of Soft X-rays with the Pixel Detector Timepix operated as a highly sensitive Dark-Current free CCD-like Camera Krejčí F. ; Kroupa M. ; Jakůbek J. ; Brůža P.; Pánek D. 2011 IEEE Nuclear Science Symposium Conference Record, NP5.S-166, 1708 - 1712 2012
Low dose X-ray phase contrast imaging sensitive to phase effects in 2-D Krejčí F. ; Jakůbek J. ; Kroupa M. IEEE NSS/MIC/RTSD Knoxville Conf. Record M09-166, doi: 10.1109/NSSMIC.2010.5874172 2010
New approach in phase contrast X-ray imaging using coded aperture Krejčí F. ; Jakůbek J. ; Kroupa M. 11th ICATPP Conference, Villa Olmo - Como (Italy), 5-9 October 2009, ISBN 10 981-4307-51-2, pp. 59 – 63 2010
Micro-Probe for Medical Radiation Imaging Based on Medipix2 Detector Vykydal Z. ; Jakůbek J. ; Svestkova M. 2009 IEEE Nuclear Science Symposium Conference Record, Pages: 2795-2797, doi: 10.1109/NSSMIC.2009.5401659 2009
Capabilities of Medipix2 and Timepix Devices as Detectors for Lobster Eye X-Ray Optics Tichy V. ; Švéda L.; Maršík J.; Jakůbek J. ; Semencová V.; Pína L.; Hudec R.; Hromčík M. ICSO 2008 Conf. Proc. 2008
Invited contribution. Energy sensitive micro-radiography and micro-tomography of biological samples allowing tissue type recognition with semiconductor pixel detectors of Medipix family Jakůbek J. EPSM ABEC 2008, Conference handbook, ISBN 0 8582 5872 2, (p. 265) 2008
Enhancement of Spatial Resolution of Roentgenographic Methods Using Deconvolution Krejčí F. ; Jakůbek J. ; Kroupa M. ; Dammer J. ; Vavřík D. IEEE NSS/MIC Conf. Proc. (2008) M06-315 2008
Enhancement of spatial resolution of roentgenographic methods Krejčí F. ; Jakůbek J. Proceedings Workshop CTU Prague Vol. 12 (2008). FYZ 026 2008
Material Analysis Using Characteristic Transmission Spectra Vavřík D. ; Jakůbek J. IEEE NSS/MIC Conf. Proc. (2008), N30-320 2008
Real-time in-vivo imaging of small organisms Dammer J. ; Jakůbek J. ; Hanus R.; Weyda F.; Vavřík D. ICATPP congf. proceedings, p. 640-644 2008
Compact system for high resolution X-ray transmission radiography, in-line phase enhanced imaging and micro CT of biological samples Jakůbek J. ; Dammer J. ; Granja C. ; Holý T. ; Pospíšil S. ; Uher J. IEEE NSS IEEE NSS Conf. Proc. 4179187 (2007) 1077-1080 2007
In-vivo real-time X-ray µ-imaging Dammer J. ; Holý T. ; Jakůbek J. ; Jakůbek M. ; Pospíšil S. ; Vavřík D. AIP Vol. 958 (2007), pp 139 2007
Microradiography with Semiconductor Pixel Detectors Jakůbek J. ; Cejnarová A. ; Dammer J. ; Holý T. ; Platkevič M. ; Pospíšil S. ; Vavřík D. ; Vykydal Z. Amer. Inst. of Physics (AIP) Conf. Proc., Volume: 958, Pages: 131-135, doi: 10.1063/1.2825764 2007
Radiography of Chaotically Moving Objects Vavřík D. ; Dammer J. ; Holý T. ; Jakůbek J. ; Jakůbek M. ; Jandejsek I. AIP Vol. 958 (2007) 139-142 2007
Spectrometric Properties of TimePix Pixel Detector for X-ray Color and Phase Sensitive Radiography Jakůbek J. ; Dammer J. ; Holý T. ; Jakůbek M. ; Pospíšil S. ; Tichy V. ; Uher J. ; Vavřík D. IEEE NSS Conf. Proc. (2007) N50-6 2007
Direct thickness calibration: way to radiographic study of soft tissues Vavřík D. ; Holý T. ; Jakůbek J. ; Pospíšil S. ; Vykydal Z. ; Dammer J. 9th ICATPP 2005 Conf. Proc., Pages: 773-778, doi: 10.1142/9789812773678_0122 2006
Microradiographic Observation of Material Damage Structure Vavřík D. ; Holý T. ; Jakůbek J. ; Jakůbek M. ; Vykydal Z. 2006 IEEE Nuclear Science Symposium Conference Record, Pages: 1081-1083, doi: 10.1109/NSSMIC.2006.356034 2006
Normalized model system for the study of termite management Tykva R.; Hanus R.; Jakůbek J. ; Wimmer Z.; Vlasáková V. XVIII World Congress IMEKO 2006
Radiographic Observation of Damage Zone Evolution in High Ductile Specimen Vavřík D. ; Holý T. ; Jakůbek J. ; Jakůbek M. ; Bryscejn J.; Tichy V. ; Vykydal Z. ; Valach J. European Conference of Fracture, Pages: 323-328, ISBN 1-4020-4971-4 2006
X-ray Micro Radiography Using Beam Hardening Correction Vavřík D. ; Holý T. ; Jakůbek J. ; Pospíšil S. ; Vykydal Z. ; Dammer J. 2005 IEEE Nuclear Science Symposium Conference Record, Pages: 2989-2992 , doi: 10.1109/NSSMIC.2005.1596959 2005
Non-destructive observation of damage processes by X-ray dynamic defectoscopy Vavřík D. ; Jakůbek J. ; Pospíšil S. ; Visschers J. International Conference on the Mechanical Behaviour of Materials, Conf. Proc. 2003
Present status of X-ray dynamic defectoscopy Vavřík D. ; Jakůbek J. ; Pospíšil S. ; Visschers J. IEEE NSS 2003 Conf. Proc. 2003
Search
10th Anniversary of IEAP