IEAP - Institute of Experimental and Applied Physics CTU - Czech Technical University in Prague
Česky English
IEAP - Institute of Experimental and Applied Physics CTU - Czech Technical University in Prague
CTU - Czech Technical University in Prague
Staff  > Vavřík Daniel, Ing., Ph.D.
Vavřík Daniel
Vavřík Daniel, Ing., Ph.D.

Department: Department of applied physics and technology
Position:
Phone number: +420 224 359 181
E-mail: Daniel.Vavrik@utef.cvut.cz
Collaboration: regular staff

Personal data

Responsible for Grants (3)
ACP2-GA-2012-314562 Quantitative Inspection of Complex Composite Aeronautic Parts Using Advanced X-ray Techniques (QUICOM) European Union Seventh Framework Programme 1.1.2012-31.12.2015
103/09/2101 Evaluation of the energy responsible for fracture advancing GAČR 1.1.2009-31.12.2012
106/04/0567 Study of damage zone in high ductile materials in vicinity of crack tip by X-Ray Dynamic Defectoscopy method GAČR 1.1.2005-1.1.2007

Articles in Impacted Journals
(24)
Table format
Year

  • D. Vavřík, J. Jakůbek, I. Jandejsek, F. Krejčí, I. Kumpová, J. Žemlička, "Visualization of delamination in composite materials utilizing advanced X-ray imaging techniques", Journal of Instrumentation 10 C04012 (2015)

  • J. Jakůbek, M. Jakůbek, M. Platkevič, P. Soukup, D. Tureček, V. Sýkora, D. Vavřík, "Large area pixel detector WIDEPIX with full area sensitivity composed of 100 Timepix assemblies with edgeless sensors", JINST 9 C04018 (2014)

  • D. Vavřík, M. Holík, J. Jakůbek, M. Jakůbek, V. Kraus, F. Krejčí, P. Soukup, D. Tureček, J. Vacík, J. Žemlička, "Modular pixelated detector system with the spectroscopic capability and fast parallel read-out ", Journal of Instrumentation 9 C06006 (2014)

  • I. Jandejsek, J. Jakůbek, M. Jakůbek, P. Průcha, F. Krejčí, P. Soukup, D. Tureček, D. Vavřík, J. Žemlička, "X-ray inspection of composite materials for aircraft structures using detectors of Medipix type", Journal of Instrumentation 9 C05062 (2014)

  • D. Vavřík, "CT Artefact Reduction by Signal to Thickness Calibration Function Shaping", NIM A, Volume 633, Supplement 1, May 2011, Pages S152-S155

  • O. Jiroušek, I. Jandejsek, D. Vavřík, "Evaluation of strain field in microstructures using micro-CT and digital volume correlation", JINST 6 C01039 doi:10.1088/1748-0221/6/01/C01039 (2011)

  • D. Vavřík, P. Soukup, "Metal Grain Structure Resolved with Table-top micro-Tomographic System", JINST_007P_1011 (2011)

  • T. Nguyen, D. Vavřík, E. Lehmann, I. Jeon, "Neutron Analysis for Microvoids in an Adhesive Layer between High X-ray Attenuation Materials", Appl. Phys. Express 4 (2011) 066401

  • D. Vavřík, J. Dammer, J. Jakůbek, I. Jeon, O. Jiroušek, M. Kroupa, P. Zlámal, "Radiography in Engineering Practice", Nucl. Instr. Methods A, Vol. 633, Suppl. 1, p. S152-S155, doi:10.1016/j.nima.2010.06.152 (2011)

  • I. Jandejsek, F. Nachtrab, N. Uhlmann, D. Vavřík, "X-ray dynamic defectoscopy utilizing digital image correlation", NIM A, Volume 633, Supplement 1, May 2011, Pages S185-S18

  • P. Frallicciardi, J. Jakůbek, D. Vavřík, "Comparison of Single Photon Counting and Charge-Integrating Detectors for X-ray High Resolution Imaging of Small Biological Objects", NIM A, Vol. 607, Issue 1, p. 221-222 (2009)

  • F. Krejčí, J. Jakůbek, J. Dammer, D. Vavřík, "Enhancement of spatial resolution of roentgenographic methods", Nucl. Instr. Methods A 607, Issue 1, 208-211 (2009)

  • D. Vavřík, J. Jakůbek, "Radiogram enhancement and linearization using the beam hardening correction method", NIM A, Vol. 607, Issue 1, p. 212-214 (2009)

  • J. Dammer, P. Frallicciardi, J. Jakůbek, M. Jakůbek, S. Pospíšil, E. Prenerová, D. Vavřík, L. Volter, F. Weyda, R. Zemek, "Real-time in-vivo µ-imaging with Medipix2", NIM A, Vol. 607, Issue 1, p. 205-207 (2009)

  • D. Vavřík, J. Jakůbek, T. Holý, "Micrometric scale measurement of material structure moving utilizing μ-radiographic technique", NIM A, Vol. 591, Issue 1, p. 24-27 (2008)

  • T. Holý, J. Jakůbek, S. Pospíšil, J. Uher, D. Vavřík, Z. Vykydal, "Data acquisition and processing software package for Medipix-2 device", Nucl. Instr. and Meth. A, Volume: 563, Issue:1, Pages: 254-258, doi: 10.1016/j.nima.2006.01.122

  • J. Jakůbek, D. Vavřík, T. Holý, M. Jakůbek, Z. Vykydal, "Experimental system for high resolution X-ray transmission radiography", Nucl. Instr. and Meth. A, Volume: 563, Issue 1, Pages: 278-281, doi: 10.1016/j.nima.2006.01.033

  • J. Jakůbek, T. Holý, E. Lehmann, S. Pospíšil, J. Uher, D. Vavřík, "Neutron Imaging with MEDIPIX2 Chip and a Coated Sensor", NIM A Vol. 560, pages 143-147 (2006)

  • J. Jakůbek, C. Granja, T. Holý, E. Lehmann, V. Linhart, S. Pospíšil, V. Rypar, J. Uher, J. Vacík, D. Vavřík, Z. Vykydal, M. Cevallos, "Neutron imaging and tomography with Medipix2 and dental microroentgenography", Nucl. Instr. and Meth. A, Volume: 569, Issue 2, Pages: 205-209, doi: 10.1016/j.nima.2006.08.043

  • J. Jakůbek, D. Vavřík, S. Pospíšil, J. Uher, "Quality of X-ray transmission radiography based on single photon counting pixel device", NIM A Vol. 546, pages 113-117 (2005)

  • J. Jakůbek, T. Holý, S. Pospíšil, J. Uher, D. Vavřík, "Spatial Resolution of the Medipix-2 as Neutron Pixel Detector", NIM A Vol. 546, pages 164-169 (2005)

  • J. Jakůbek, T. Holý, S. Pospíšil, J. Uher, D. Vavřík, "Properties of the single neutron pixel detector based on the Medipix-1 device", NIM A Vol. 531, pages 276-284 (2004)

  • J. Jakůbek, T. Holý, S. Pospíšil, D. Vavřík, "Tomography for XRDD", NIM A Vol. 531, pages 307-313 (2004)

  • J. Jakůbek, S. Pospíšil, D. Vavřík, J. Visschers, "Resolution and stability tests of a Medipix-1 pixel detector for X-ray dynamic defectoscopy", NIM A Vol. 509, pages 294-301 (2003)
Search
10th Anniversary of IEAP