IEAP - Institute of Experimental and Applied Physics CTU - Czech Technical University in Prague
Česky English
IEAP - Institute of Experimental and Applied Physics CTU - Czech Technical University in Prague
CTU - Czech Technical University in Prague
Staff  > Vavřík Daniel, Ing., Ph.D.
Vavřík Daniel
Vavřík Daniel, Ing., Ph.D.

Department: Department of applied physics and technology
Position:
Phone number: +420 224 359 181
E-mail: Daniel.Vavrik@utef.cvut.cz
Collaboration: regular staff

Personal data

Responsible for Grants (3)
ACP2-GA-2012-314562 Quantitative Inspection of Complex Composite Aeronautic Parts Using Advanced X-ray Techniques (QUICOM) European Union Seventh Framework Programme 1.1.2012-31.12.2015
103/09/2101 Evaluation of the energy responsible for fracture advancing GAČR 1.1.2009-31.12.2012
106/04/0567 Study of damage zone in high ductile materials in vicinity of crack tip by X-Ray Dynamic Defectoscopy method GAČR 1.1.2005-1.1.2007

Articles in Impacted Journals
(24)
Text format
Year

Ocenění OceněníName Author Scientific journal Year
CT Artefact Reduction by Signal to Thickness Calibration Function Shaping Vavřík D. NIM A, Volume 633, Supplement 1, May 2011, Pages S152-S155 2011
Comparison of Single Photon Counting and Charge-Integrating Detectors for X-ray High Resolution Imaging of Small Biological Objects Frallicciardi P.; Jakůbek J.; Vavřík D. NIM A, Vol. 607, Issue 1, p. 221-222 2009
Data acquisition and processing software package for Medipix-2 device Holý T.; Jakůbek J.; Pospíšil S.; Uher J.; Vavřík D.; Vykydal Z. Nucl. Instr. and Meth. A, Volume: 563, Issue:1, Pages: 254-258, doi: 10.1016/j.nima.2006.01.122 2006
Enhancement of spatial resolution of roentgenographic methods Krejčí F.; Jakůbek J.; Dammer J.; Vavřík D. Nucl. Instr. Methods A 607, Issue 1, 208-211 2009
Evaluation of strain field in microstructures using micro-CT and digital volume correlation Jiroušek O.; Jandejsek I.; Vavřík D. JINST 6 C01039 doi:10.1088/1748-0221/6/01/C01039 2011
Experimental system for high resolution X-ray transmission radiography Jakůbek J.; Vavřík D.; Holý T.; Jakůbek M.; Vykydal Z. Nucl. Instr. and Meth. A, Volume: 563, Issue 1, Pages: 278-281, doi: 10.1016/j.nima.2006.01.033 2006
Large area pixel detector WIDEPIX with full area sensitivity composed of 100 Timepix assemblies with edgeless sensors Jakůbek J.; Jakůbek M.; Platkevič M.; Soukup P.; Tureček D.; Sýkora V.; Vavřík D. JINST 9 C04018 2014
Metal Grain Structure Resolved with Table-top micro-Tomographic System Vavřík D.; Soukup P. JINST_007P_1011 2011
Micrometric scale measurement of material structure moving utilizing μ-radiographic technique Vavřík D.; Jakůbek J.; Holý T. NIM A, Vol. 591, Issue 1, p. 24-27 2008
Modular pixelated detector system with the spectroscopic capability and fast parallel read-out Vavřík D.; Holík M.; Jakůbek J.; Jakůbek M.; Kraus V.; Krejčí F.; Soukup P.; Tureček D.; Vacík J.; Žemlička J. Journal of Instrumentation 9 C06006 2014
Neutron Analysis for Microvoids in an Adhesive Layer between High X-ray Attenuation Materials Nguyen T.; Vavřík D.; Lehmann E.; Jeon I. Appl. Phys. Express 4 (2011) 066401 2011
Invited contribution to conference VERTEX 2004, Como, Italy Neutron Imaging with MEDIPIX2 Chip and a Coated Sensor Jakůbek J.; Holý T.; Lehmann E.; Pospíšil S.; Uher J.; Vavřík D. NIM A Vol. 560, pages 143-147 2006
Neutron imaging and tomography with Medipix2 and dental microroentgenography Jakůbek J.; Granja C.; Holý T.; Lehmann E.; Linhart V.; Pospíšil S.; Rypar V.; Uher J.; Vacík J.; Vavřík D.; Vykydal Z.; Cevallos M. Nucl. Instr. and Meth. A, Volume: 569, Issue 2, Pages: 205-209, doi: 10.1016/j.nima.2006.08.043 2006
Properties of the single neutron pixel detector based on the Medipix-1 device Jakůbek J.; Holý T.; Pospíšil S.; Uher J.; Vavřík D. NIM A Vol. 531, pages 276-284 2004
Quality of X-ray transmission radiography based on single photon counting pixel device Jakůbek J.; Vavřík D.; Pospíšil S.; Uher J. NIM A Vol. 546, pages 113-117 2005
Radiogram enhancement and linearization using the beam hardening correction method Vavřík D.; Jakůbek J. NIM A, Vol. 607, Issue 1, p. 212-214 2009
Radiography in Engineering Practice Vavřík D.; Dammer J.; Jakůbek J.; Jeon I.; Jiroušek O.; Kroupa M.; Zlámal P. Nucl. Instr. Methods A, Vol. 633, Suppl. 1, p. S152-S155, doi:10.1016/j.nima.2010.06.152 2011
Real-time in-vivo µ-imaging with Medipix2 Dammer J.; Frallicciardi P.; Jakůbek J.; Jakůbek M.; Pospíšil S.; Prenerová E.; Vavřík D.; Volter L.; Weyda F.; Zemek R. NIM A, Vol. 607, Issue 1, p. 205-207 2009
Resolution and stability tests of a Medipix-1 pixel detector for X-ray dynamic defectoscopy Jakůbek J.; Pospíšil S.; Vavřík D.; Visschers J. NIM A Vol. 509, pages 294-301 2003
Spatial Resolution of the Medipix-2 as Neutron Pixel Detector Jakůbek J.; Holý T.; Pospíšil S.; Uher J.; Vavřík D. NIM A Vol. 546, pages 164-169 2005
Tomography for XRDD Jakůbek J.; Holý T.; Pospíšil S.; Vavřík D. NIM A Vol. 531, pages 307-313 2004
Visualization of delamination in composite materials utilizing advanced X-ray imaging techniques Vavřík D.; Jakůbek J.; Jandejsek I.; Krejčí F.; Kumpová I.; Žemlička J. Journal of Instrumentation 10 C04012 2015
X-ray dynamic defectoscopy utilizing digital image correlation Jandejsek I.; Nachtrab F.; Uhlmann N.; Vavřík D. NIM A, Volume 633, Supplement 1, May 2011, Pages S185-S18 2011
X-ray inspection of composite materials for aircraft structures using detectors of Medipix type Jandejsek I.; Jakůbek J.; Jakůbek M.; Průcha P.; Krejčí F.; Soukup P.; Tureček D.; Vavřík D.; Žemlička J. Journal of Instrumentation 9 C05062 2014
Search
10th Anniversary of IEAP