Radiogram enhancement and linearization using the beam hardening correction method

Author

Year
2009

Scientific journal
NIM A, Vol. 607, Issue 1, p. 212-214

Web


Abstract
Traditionally, radiography is burdened by the fact that standard X-ray tube spectra are polychromatic and attenuation process in matter is energy dependent where low-energy X-rays are preferentially absorbed. This beam hardening effect has several consequences: radiograms look noisy especially when low energy photons are detected, empty holes look filled in Computed Tomography due to nonlinear dependence between radiogram and specimen thickness, and from the same reason, observed object looks more flat than it should be. It will be shown it this paper that these problems can be solved using the “Linearized Signal to Equivalent Thickness” beam hardening correction method.