IEAP - Institute of Experimental and Applied Physics CTU - Czech Technical University in Prague
Česky English
IEAP - Institute of Experimental and Applied Physics CTU - Czech Technical University in Prague
CTU - Czech Technical University in Prague
Publication  > Articles in Impacted Journals  > 'Influence of electromagnetic interference on the analog part of hybrid Pixel detectors'
Influence of electromagnetic interference on the analog part of hybrid Pixel detectors

Author

Year
2011

Scientific journal
JINST 6 C12028, doi:10.1088/1748-0221/6/12/C12028

Web


Abstract
The analog signal from the sensor of hybrid semiconductor pixel detectors is prone to electro-magnetic interference. The study and diagnosis of induced and common electro-magnetic coupling between the analog part and digital part of these devices is required. The influence of electro-magnetic interference was tested on the setup with a pixel detector Timepix or Medipix and a FITPix read-out interface. Measurements were carried out of external as well as internal interference. We evaluated the influence of both sources of electro-magnetic interference to the noise recorded by pixels. We measured the local spatial intensity distribution and frequency spectrum of the electro-magnetic field originating inside the readout chip during its own operation. In context of this test we exposed the detector chip to a locally generated artificial electro-magnetic field evaluating its sensitivity to induced interference. Consequently, the whole setup of the detector and read-out interface was exposed to a distant source of electro-magnetic radiation, during which we tested efficiency of the electro-magnetic shielding of various arrangements. Further, tests measured the coupling over power supply lines. In particular, the noise generated by the operation of the detector itself was determined. In addition, the detector sensitivity to deliberately induced noise was evaluated. By means of these tests weak points of the setup sensitive to the intrusion of electro-magnetic interference are revealed. When locations of susceptible places are identified proper methods can be applied to increase immunity of the detector setup against the electro-magnetic interference. Experiences gained are planned to be used in development of the EMI shielded version of the FITPIX interface shielded to electro-magnetic interference
Grants

Projects


Cite article as:
M. Holík, V. Kraus, C. Granja, J. Jakůbek, V. Georgiev, M. Hromadka, J. Skala, Z. Kubik, "Influence of electromagnetic interference on the analog part of hybrid Pixel detectors", JINST 6 C12028, doi:10.1088/1748-0221/6/12/C12028 (2011)

Search
10th Anniversary of IEAP