IEAP - Institute of Experimental and Applied Physics CTU - Czech Technical University in Prague
Česky English
IEAP - Institute of Experimental and Applied Physics CTU - Czech Technical University in Prague
CTU - Czech Technical University in Prague
Publication  > Articles in Impacted Journals  > 'Gamma-ray flux in the Fréjus underground laboratory measured with NaI detector'
Gamma-ray flux in the Fréjus underground laboratory measured with NaI detector

Author

Year
2002

Scientific journal
Nucl. Instr. and Meth. in Phys. Res. A482 (2002) pp. 832-839


Abstract
The γ-ray flux in the Fréjus underground laboratory has been studied using an NaI detector surrounded by different diagonostic shields. Below 4 MeV, the spectrum is dominated by radioactivities in the surrounding materials and rocks. Between 4 and 6 MeV, the shape of the spectrum is well explained by U, Th and daughters, which are internal contaminations in the NaI crystal. Between 6 and 10 MeV, the γ-ray flux is strongly correlated with neutron captures in the surrounding materials. Finally, the γ-ray flux above 10 MeV falls off and is related to the very weak cosmic muon flux via muon bremsstrahlung.

Cite article as:
H. Ohsumi, I. Štekl, L. Vála, V. Vorobel, . NEMO Collaboration, "Gamma-ray flux in the Fréjus underground laboratory measured with NaI detector", Nucl. Instr. and Meth. in Phys. Res. A482 (2002) pp. 832-839 (2002)

Search
10th Anniversary of IEAP