IEAP - Institute of Experimental and Applied Physics CTU - Czech Technical University in Prague
Česky English
IEAP - Institute of Experimental and Applied Physics CTU - Czech Technical University in Prague
CTU - Czech Technical University in Prague
Publication  > Articles in Impacted Journals  > 'Energy sensitive Timepix silicon detector for electron imaging'
Energy sensitive Timepix silicon detector for electron imaging

Author
Esposito M. Dipartimento di Scienze Fisiche, Università di Napoli Federico II, I-80126 Napoli, Italy
Jakůbek Jan, Ing. Ph.D. IEAP
Mettivier Giovanni Dipartimento di Scienze Fisiche, Università di Napoli Federico II, and INFN, Sezione di Napoli
Pospíšil Stanislav,  Ing. DrSc. IEAP
Russo Paolo Dipartimento di Scienze Fisiche, Università di Napoli Federico II, and INFN, Sezione di Napoli
Šolc Jaroslav, Ing. Ph.D. IEAP

Year
2011

Scientific journal
NIM A, Vol. 652, Issue 1, 458-461, doi:10.1016/j.nima.2011.01.148

Web


Abstract
We present the first measurements with the energy sensitive Timepix pixel detector for electron imaging. The hybrid pixel detector consists of a silicon detector, 300 μm thick, bump-bonded to the Timepix readout chip developed by the Medipix2 collaboration (256×256 pixels, 55 μm pitch, 14.08×14.08 mm2 sensitive area). Each Timepix pixel can be independently operated in one of three modes: 1. counting of the detected particles; 2. measurement of the particle energy; 3. measurement of the time of particle interaction. The energy measurement in the second mode is performed via the determination of the “Time-Over-Threshold” (TOT). The ionization charge generated by the particle along its track is often registered by several adjacent pixels forming a cluster. The shape of the cluster is affected also by lateral charge spread. It is often possible to determine a particle type, its energy, entrance point and direction by on-line or off-line analysis of shapes of recorded clusters. This way an influence of background or noise can be significantly reduced in measured data. The energy spectrum for 90Sr/90Y electrons was measured by Timepix detector and compared with the β− decay spectrum and the Monte Carlo simulated spectrum. In order to improve spatial resolution, we analyzed the tracks of all electrons and substituted each cluster with the position of its centroid. We measured the spatial resolution with a 90Sr/90Y source irradiating at 10 cm distance, a 100 μm thick steel edge slightly tilted with respect to the detector lines. The oversampled Line Spread Function shows an FWHM of 27.5±1.1 μm. The Timepix Si detector will be used for digital autoradiography with β− and β+ tracers, and it could be used for electron microscopy. First tests were performed with a 14C autoradiography sample.
Grants

Projects


Cite article as:
M. Esposito, J. Jakůbek, G. Mettivier, S. Pospíšil, P. Russo, J. Šolc, "Energy sensitive Timepix silicon detector for electron imaging", NIM A, Vol. 652, Issue 1, 458-461, doi:10.1016/j.nima.2011.01.148 (2011)

Search
10th Anniversary of IEAP