IEAP - Institute of Experimental and Applied Physics CTU - Czech Technical University in Prague
Česky English
IEAP - Institute of Experimental and Applied Physics CTU - Czech Technical University in Prague
CTU - Czech Technical University in Prague
Publication  > Articles in Impacted Journals  > 'Real-time in-vivo µ-imaging with Medipix2'
Real-time in-vivo µ-imaging with Medipix2

Author
Dammer Jiří, Mgr. IEAP
Frallicciardi Paola Maria, Mgr. Dipartimento di Scienze Fisiche, Universita’ degli Studi di Napoli ”Federico II”, Napoli, Italy
Jakůbek Jan, Ing. Ph.D. IEAP
Jakůbek Martin, Ing. IEAP
Pospíšil Stanislav,  Ing. DrSc. IEAP
Prenerová Eva, Ing. CSc. Laboratory of Plant Protection Olesna
Vavřík Daniel, Ing., Ph.D. IEAP
Volter Lubomír, Mgr. Biology Centre of the Academy of Sciences of the Czech Republic, v. v. i.
Weyda František, doc. RNDr. CSc. Biology Centre of the Academy of Sciences of the Czech Republic, v. v. i.
Zemek Rostislav, Ing. CSc. Biology Centre of the Academy of Sciences of the Czech Republic, v. v. i.

Year
2009

Scientific journal
NIM A, Vol. 607, Issue 1, p. 205-207

Web


Abstract
An X-ray micro-radiographic system based on the Medipix2 semiconductor pixel detector for dynamic high spatial resolution and high contrast imaging has been developed. Our system is founded on a micro-focus and nano-focus X-ray tube and the hybrid single photon counting silicon pixel detector Medipix2 (matrix 256 x 256 sq. pixels of 55 µm pitch). This compact table-top system stands promising as a new tool in the field of small animal imaging as well as the in-vivo observation of dynamic processes inside living organisms. The main advantages of these Medipix2 pixel detectors include: high sensitivity to low energy X-ray photons; position sensitive and noiseless single photon detection with preselected photon energies; single-quantum counting in each pixel performed by digital counter (therefore there is no dark current); digital integration (providing unlimited dynamic range and absolute linearity in device response to number of photons, high sensitivity and high contrast); real-time digital information, high speed digital communication and data transfer. We improve the picture quality with the help of statistical data analysis and extended calibration of individual pixels response. Obtained 2D and 3D radiographic images of small insects demonstrate the potential and applicability of our system for precise in-vivo x-ray high resolution dynamic diagnostic and biological studies.