IEAP - Institute of Experimental and Applied Physics CTU - Czech Technical University in Prague
Česky English
IEAP - Institute of Experimental and Applied Physics CTU - Czech Technical University in Prague
CTU - Czech Technical University in Prague
Staff  > Jakůbek Jan, Ing. Ph.D.
Jakůbek Jan
Jakůbek Jan, Ing. Ph.D.

Department: Department of applied physics and technology
Position: Leader
Phone number: +420 224 359 181
E-mail: jan.jakubek@utef.cvut.cz
Collaboration: regular staff

Personal data
Born:
October 22, 1969, Nový Jičín, Czech Republic.

Education:
1993 Graduated in Mathematical Engineering at Faculty of Nuclear Science and Physical Engineering (FNSPE) of the Czech Technical University in Prague (CTU)
2001 PhD degree in Nuclear Physics at FNSPE CTU

Former positions:
1997-2000 Faculty of nuclear science and physical engineering, CTU, teacher.
2001-2001 Neovision ltd., development of optical measurement methods.
2001-2002 miniRAD ltd., development of a software and hardware for small DAQ systems.
2002- now Institute of Experimental and Applied Physics CTU, senior researcher, head of department of applied physics and technology.

Main research activities and interests:
  • Nuclear imaging (Medipix),
  • Study of semiconductor detection structures and their practical applications,
  • Spectroscopy, multiparametric coincidence spectroscopy,
  • Mathematical analysis of data taken from physical experiments,
  • Instrumentation for nuclear experiments.

Responsible for Grants (12)
TE01020455 Centre for Advanced Nuclear Technologies (CANUT) GAČR 1.3.2012-31.12.2019
DF12P01OVV048 New portable instruments, laboratory and methodology for the non-destructive materials analysis of the fine art in the frame of cultural heritage protection MK 1.3.2012-31.12.2015
TA01010164 Advanced Techniques for Detection of Ionizing Radiation TAČR 1.1.2011-31.12.2014
P105/11/1551 Energetic and stress state aspects of quasi-brittle fracture – consequences for determination of fracture-mechanical parameters of silicate composites GAČR 1.1.2011-31.12.2013
TA01010237 Facility for nondestructive testing, diagnostics and 3D imaging based on neutron radiography and tomography TAČR 1.1.2011-31.12.2015
OHK4-002/10 Design of 3D detector of ionizing radiation - voxel detector IGS ČVUT 1.1.2010-31.12.2011
PN1 3-01-546 Characterization of Pixel DetectorTimePix for Spectroscopy of Fission Fragments and their Decay Radiation ILL Grenoble 1.1.2009-31.12.2009
103/09/2101 Evaluation of the energy responsible for fracture advancing GAČR 1.1.2009-31.12.2012
PF2 UCN 3-14-239 Test of Medipix Detector with UCN converter coating ILL Grenoble 1.1.2008-31.12.2008
MSM 6840770040 Research Program 40: Usage of radionuclides and ionizing radiation. MŠMT 1.1.2007-31.12.2012
LC06041 Research center "Fabrication, modification and characterization of materials by energetic radiation" MŠMT 1.4.2006-30.12.2011
106/04/0567 Study of damage zone in high ductile materials in vicinity of crack tip by X-Ray Dynamic Defectoscopy method GAČR 1.1.2005-1.1.2007

Articles in Impacted Journals
(123)
Text format
Year

Ocenění Name Author Scientific journal OceněníYear
Visualization of delamination in composite materials utilizing advanced X-ray imaging techniques Vavřík D.; Jakůbek J.; Jandejsek I.; Krejčí F.; Kumpová I.; Žemlička J. Journal of Instrumentation 10 C04012 2015
X-ray micro-CT scanner for small animal imaging based on Timepix detector technology Dudák J.; Žemlička J.; Krejčí F.; Polanský Š.; Jakůbek J.; Mrzílková J.; Patzelt M.; Trnka J. Nucl. Instr. Methods A 773, 81-86 2015
Energy resolution and power consumption of Timepix detector for different detector settings and saturation of front-end electronics Kroupa M.; Hoang S.; Stoffle N.; Soukup P.; Jakůbek J.; Pinsky L. JINST 2014
Fast Spectroscopic Imaging with Pixel Semiconductor Detector Timepix and Parallel Data Reading Žemlička J.; Holík M.; Kraus V.; Jakůbek J. Journal of Instrumentation 2014
High-contrast X-ray Radiography Using Hybrid Semiconductor Pixel Detectors with 1 mm thick Si sensor as a Tool for Monitoring Liquids in Natural Building Krejčí F.; Slavíková M.; Žemlička J.; Jakůbek J.; Kotlík P. Journal of Instrumentation 9 C07014 2014
Large area pixel detector WIDEPIX with full area sensitivity composed of 100 Timepix assemblies with edgeless sensors Jakůbek J.; Jakůbek M.; Platkevič M.; Soukup P.; Tureček D.; Sýkora V.; Vavřík D. JINST 9 C04018 2014
Modular pixelated detector system with the spectroscopic capability and fast parallel read-out Vavřík D.; Holík M.; Jakůbek J.; Jakůbek M.; Kraus V.; Krejčí F.; Soukup P.; Tureček D.; Vacík J.; Žemlička J. Journal of Instrumentation 9 C06006 2014
Neutron and high-contrast X-ray micro-radiography as complementary tools for monitoring organosilicon consolidants in natural building stones Slavíková M.; Krejčí F.; Kotlík P.; Jakůbek J.; Tomandl I.; Vacík J. Nucl. Instr. Methods B: Beam Interactions with Materials and Atoms 338, 42-47 2014
Study of Edgeless Radiation Detector with 3D Spatial Mapping Technique Wu X.; Kalliopuska J.; Jakůbek M.; Jakůbek J.; Gäddä A.; Eränen S. JINST 9 C04004 2014
X-ray inspection of composite materials for aircraft structures using detectors of Medipix type Jandejsek I.; Jakůbek J.; Jakůbek M.; Průcha P.; Krejčí F.; Soukup P.; Tureček D.; Vavřík D.; Žemlička J. Journal of Instrumentation 9 C05062 2014
3D imaging of radiation damage in silicon sensor and spatial mapping of charge collection efficiency Jakůbek M.; Jakůbek J.; Žemlička J.; Platkevič M.; Havránek V.; Semian V. JINST 8 C03023 2013
BrachyView, A novel inbody imaging system for HDR prostate brachytherapy: Design and Monte Carlo feasibility study Safavi-Naeini M.; Han Z.; Cutajar D.; Guatelli S.; Petasecca M.; Lerch M.; Franklin D.; Jakůbek J.; Pospíšil S.; Bucci J.; Zaider M.; Rosenfeld A. MEDICAL PHYSICS, Volume 40, Issue 7, Article Number: 071715 DOI: 10.1118/1.4808360 2013
BrachyView: Proof-of-principle of a novel in-body gamma camera for low dose-rate prostate brachytherapy Petasecca M.; Loo K.; Safavi-Naeini M.; Han Z.; Metcalfe P.; Meikle S.; Pospíšil S.; Jakůbek J.; Bucci J.; Zaider M.; Lerch M.; Qi Y.; Rosenfeld A. MEDICAL PHYSICS, Volume: 40, Issue: 4, Article Number: 041709, DOI: 10.1118/1.4794487 2013
Directional Detection of Fast Neutrons by the Timepix Pixel Detector Coupled to Plastic Scintillator with Silicon Photomultiplier Array Mašek P.; Jakůbek J.; Uher J.; Preston R. JINST 8 C01021 2013
Energy loss and online directional track visualization of fast electrons with the pixel detector Timepix Granja C.; Krist P.; Chvatil D.; Šolc J.; Pospíšil S.; Jakůbek J.; Opalka L. Rad. Measurements 59 (2013) 245-261 2013
Evaluation of local radiation damage in silicon sensor via charge collection mapping with the Timepix read-out chip Platkevič M.; Jakůbek J.; Havránek V.; Jakůbek M.; Semian V.; Žemlička J. JINST 8 C04001 2013
Linear energy transfer and track pattern recognition of secondary radiation generated in hadron therapy beam in a PMMA target Opalka L.; Granja C.; Jakůbek J.; Pospíšil S.; Šolc J.; Hartmann B.; Martisikova M.; Jaekel O. J.of Instrumentation JINST 8 (2013) C02047 2013
Measurement of radon activity in air using electrostatic collection to the Timepix detector Mamedov F.; Čermák P.; Jakůbek J.; Smolek K.; Štekl I.; Vlášek J. JINST, Volume: 8, Article Number: C03011, DOI: 10.1088/1748-0221/8/03/C03011 2013
Multimodal imaging with hybrid semiconductor detectors Timepix for an experimental MRI-SPECT system Zajíček J.; Jakůbek J.; Burian M.; Vobecký M.; Fauler A.; Fiederle M.; Zwerger A. Journal of Instrumentation 2013
Non-invasive monitoring of therapeutic carbon ion beams in a homogeneous phantom by tracking of secondary ions Gwosch K.; Hartmann B.; Jakůbek J.; Granja C.; Soukup P.; Martisikova M.; Jaekel O. Physics in Medicine and Biology, Vol. 58, p3755, doi:10.1088/0031-9155/58/11/3755 2013
Processing and characterization of edgeless radiation detectors for large area detection Kalliopuska J.; Wu X.; Jakůbek J.; Eränen S.; Virolainen T. Nuclear Instruments and Methods in Physics Research A, Volume 731, p. 205-209 2013
Ultra-stable implanted Rb-83/Kr-83m electron sources for the energy scale monitoring in the KATRIN experiment Zboril M.; Bauer S.; Beck M.; Bonn J.; Dragoun O.; Jakůbek J.; Johnston K.; Kovalik A.; Otten E.; Schlosser K.; Slezak M.; Spalek A.; Thummler T.; Venos D.; Žemlička J.; Weinheimer C. JINST, Volume: 8 Article Number: P03009 DOI: 10.1088/1748-0221/8/03/P03009 2013
2012 International Science & Engineering Visualization Challenge - Honorable Mention X-ray micro-radiography and microscopy of seeds Sýkora V.; Žemlička J.; Krejčí F.; Jakůbek J. Science 339 (6119), 511 2013
3D measurement of the radiation distribution in a water phantom in a hadron therapy beam Opalka L.; Granja C.; Hartmann B.; Jakůbek J.; Jaekel O.; Martisikova M.; Pospíšil S.; Solc J. J.of Instrumentation 7 (2012) C01085 2012
Initial results on charge and velocity discrimination for heavy ions using silicon-Timepix detectors Stoffle N.; Pinsky L.; Hoang S.; Idarraga J.; Kroupa M.; Jakůbek J.; Tureček D.; Pospíšil S. Journal of Instrumentation 2012
Mobile system for in-situ imaging of cultural objects Žemlička J.; Jakůbek J.; Krejčí F.; Hradil D.; Hradilová J.; Mislerová H. Journal of Instrumentation 7 C01108 2012
Pixel detector Timepix operated in pile-up mode for pulsed imaging with ultra-soft X-rays Krejčí F.; Jakůbek J.; Kroupa M.; Brůža P.; Pánek D. Journal of Instrumentation 7 C12013 2012
Probe and scanning system for 3D response mapping of pixelated semiconductor detector with X-rays and the timepix device Jakůbek M.; Jakůbek J.; Žemlička J.; Kroupa M.; Krejčí F. AIP Conf. Proc. 1423, pp. 461-466; doi:10.1063/1.3688846 2012
Proton beam characterisation of a prototype thin-tile plastic scintillator detector with SiPM readout for use in fast-neutron tracker Preston R.; Jakůbek J.; Prokopovich D.; Uher J. JINST 7 P02007 doi:10.1088/1748-0221/7/02/P02007 2012
X-ray Radiography and Tomography for Monitoring the Penetration Depth of Consolidants in Opuka - the Building stone of Prague Monuments Slavíková M.; Krejčí F.; Žemlička J.; Pech M.; Kotlík P.; Jakůbek J. Journal of Cultural Heritage 13 (4), 357-364 2012
3D sensitive voxel detector of ionizing radiation based on Timepix device Soukup P.; Jakůbek J.; Vykydal Z. Journal of Instrumentation 6 C01060, doi: 10.1088/1748-0221/6/01/C01060 2011
Absorption and Phase X-ray Imaging Using Reflected Beam Jakůbek J. NIM A, 633-1, S172-S174, doi:10.1016/j.nima.2010.06.158 2011
Analogue signal from common electrode of pixelated detector for triggering and spectroscopy Platkevič M.; Jakůbek J.; Vykydal Z.; Granja C. Journal of Instrumentation 6 C11023 doi:10.1088/1748-0221/6/11/C11023 2011
Analysis of painted arts by energy sensitive radiographic techniques with the Pixel Detector Timepix Žemlička J.; Jakůbek J.; Kroupa M.; Hradil D.; Hradilová J.; Mislerová H. Journal of Instrumentation 6 C01066, doi: 10.1088/1748-0221/6/01/C01066 2011
Application of the Medipix2 technology to space radiation dosimetry and hadron therapy beam monitoring Pinsky L.; Stoffle N.; Jakůbek J.; Pospíšil S.; Leroy C.; Gutierrez A.;  H.; Yasuda N.; Uchihori Y. Nucl. Instr. Methods A, Volume 628, Issue 1, Pages 226-229, doi:10.1016/j.nima.2010.06.323 2011
Background capabilities of pixel detectors for double beta decay measurements Čermák P.; Štekl I.; Bočarov V.; Jakůbek J.; Pospíšil S.; Fiederle M.; Fauler A.; Zuber K.; Loaiza P.; Shitov Y.; Madathiparambil Jose J. NIM A 2011
Coincidence Imaging System with Electron Optics Kroupa M.; Jakůbek J.; Krejčí F.; Žemlička J.; Horáček M.; Radlička T.; Vlček I. Nucl. Instr. Methods A 633, Suppl. 1, S270-S273 2011
Direct Observation of Decay of Radioactive Nuclei with Spatial and Time Coincidence Technique Jakůbek J.; Platkevič M.; Granja C.; Koester U.; Pospíšil S. Nucl. Instr. Methods A 633 (2011) S203-S205 2011
Energy sensitive Timepix silicon detector for electron imaging Esposito M.; Jakůbek J.; Mettivier G.; Pospíšil S.; Russo P.; Šolc J. NIM A, Vol. 652, Issue 1, 458-461, doi:10.1016/j.nima.2011.01.148 2011
Evaluation of a YAG:Ce scintillation crystal based CCD X-ray imaging detector with the Medipix2 detector Tous J.; Blazek J.; Žemlička J.; Jakůbek J. JINST 6 C11011 doi:10.1088/1748-0221/6/11/C11011 2011
FITPix – Fast Interface for Timepix Pixel Detectors Kraus V.; Holík M.; Jakůbek J.; Kroupa M.; Soukup P.; Vykydal Z. Journal of Instrumentation 6 C01079, doi: 10.1088/1748-0221/6/01/C01079 2011
High Contrast Laminography Using Iterative Algorithms Kroupa M.; Jakůbek J. JINST 6 C01045, doi: 10.1088/1748-0221/6/01/C01045 2011
Image processing for X-ray transmission radiography with 3D voxel detector Jandejsek I.; Soukup P.; Jakůbek J. JINST 6 C12061 doi:10.1088/1748-0221/6/12/C12061 2011
Influence of electromagnetic interference on the analog part of hybrid Pixel detectors Holík M.; Kraus V.; Granja C.; Jakůbek J.; Georgiev V.; Hromadka M.; Skala J.; Kubik Z. JINST 6 C12028, doi:10.1088/1748-0221/6/12/C12028 2011
MEDIPIX/TIMEPIX cosmic ray tracking on BEXUS stratospheric balloon flights Urbář J.; Scheirich J.; Jakůbek J. Nucl. Instr. Methods A, Vol. 633, Suppl. 1, p. S206-S209, doi:10.1016/j.nima.2010.06.168 2011
Measurement of pattern recognition efficiency of tracks generated by ionizing radiation in a Medipix2 device Bouchami J.; Gutierrez A.; Holý T.; Houdayer A.; Jakůbek J.; Lebel C.; Leroy C.; Macana J.; Martin J.; Pospíšil S.; Prak S.; Sabella P.; Teyssier C. Nucl. Instr. Methods A, Vol. 633, Suppl. 1, p. S187-S189, doi:10.1016/j.nima.2010.06.163 2011
Measurement of secondary radiation during ion beam therapy with the pixel detector Timepix Martisikova M.; Jakůbek J.; Granja C.; Hartmann B.; Opalka L.; Pospíšil S.; Jaekel O. JINST 6 (2011) C11014 2011
Medipix2 based CdTe microprobe for dental imaging Vykydal Z.; Fauler A.; Fiederle M.; Jakůbek J.; Švestková M.; Zwerger A. Journal of Instrumentation 6 C12002 doi:10.1088/1748-0221/6/12/C12002 2011
Award for the first best poster Microradiography of biological samples with Timepix Dammer J.; Weyda F.; Benes J.; Sopko V.; Jakůbek J.; Vondracek V. JINST 6 C11005 doi:10.1088/1748-0221/6/11/C11005 2011
Penetrating heavy ion charge and velocity discrimination with a TimePix-based Si detector (for space radiation applications) Pinsky L.; Empl A.; Gutierrez A.; Jakůbek J.; Kitamura H.; Miller J.; Leroy C.; Stoffle N.; Pospíšil S.; Uchihori Y.; Yasuda N.; Zeitlin C. Nucl. Instr. Methods A, Vol. 633, Suppl. 1, p. S190-S193, doi:10.1016/j.nima.2010.06.164 2011
Pixelman: a multi-platform data acquisition and processing software package for Medipix2, Timepix and Medipix3 detectors Tureček D.; Holý T.; Jakůbek J.; Pospíšil S.; Vykydal Z. Journal of Instrumentation 6 C01046, doi: 10.1088/1748-0221/6/01/C01046 2011
Precise Energy Calibration of Pixel Detector Working in Time-Over-Threshold Mode Jakůbek J. Nucl. Instr. Methods A, Volume 633, Supplement 1, May 2011, Pages S262-S266, doi:10.1016/j.nima.2010.06.183 2011
Quantized hard-x-ray phase vortices nucleated by aberrated nanolenses Pavlov K.; Paganin D.; Vine D.; Schmalz J.; Suzuki Y.; Uesugi K.; Takeuchi A.; Yagi N.; Kharchenko A.; Blaj G.; Jakůbek J.; Atissimo M.; Clark J. Physical Review A, Vol.83, Issue 1, 013813,doi: 10.1103/PhysRevA.83.013813 2011
Radiography in Engineering Practice Vavřík D.; Dammer J.; Jakůbek J.; Jeon I.; Jiroušek O.; Kroupa M.; Zlámal P. Nucl. Instr. Methods A, Vol. 633, Suppl. 1, p. S152-S155, doi:10.1016/j.nima.2010.06.152 2011
Response of the Pixel Detector TimePix to Heavy Ions Granja C.; Jakůbek J.; Koester U.; Platkevič M.; Pospíšil S. Nucl. Instr. Methods A 633 (2011) S198-S202 2011
Selective detection of secondary particles and neutrons produced in ion beam therapy with 3D sensitive voxel detector Jakůbek J.; Granja C.; Hartmann B.; Jäkel O.; Martisikova M.; Opalka L.; Pospíšil S. JINST 6 C12010, doi:10.1088/1748-0221/6/12/C12010 2011
Semiconductor pixel detector with absorption grid as a tool for charge sharing studies and energy resolution improvement Krejčí F.; Jakůbek J.; Kroupa M.; Jurka V.; Hruška K. Journal of Instrumentation 6 C12034 2011
Single grating method for low dose 1-D and 2-D phase contrast X-ray imaging Krejčí F.; Jakůbek J.; Kroupa M. Journal of Instrumentation 6 C01073 2011
Slow-neutron-induced charged-particle emission-channeling-measurements with Medipix detectors Koester U.; Granja C.; Jakůbek J.; Uher J.; Vacík J. Nucl. Instr. Methods A 633 (2011) S267-S269 2011
Small Dosimeter based on Timepix device for International Space Station Tureček D.; Pinsky L.; Jakůbek J.; Vykydal Z.; Stoffle N.; Pospíšil S. Journal of Instrumentation 6 C12037, doi: 10.1088/1748-0221/6/12/C12037 2011
Study of the charge sharing in silicon pixel detector by means of heavy ionizing particles interacting with a Medipix2 device Bouchami J.; Gutierrez A.; Houdayer A.; Jakůbek J.; Lebel C.; Leroy C.; Macana J.; Martin J.; Platkevič M.; Pospíšil S.; Teyssier C. Nucl. Instr. Methods A. Vol. 607, Issue 1, 1 p. 196-198, doi:10.1016/j.nima.2009.03.147 2011
Tests of Lobster Eye Optics for Small Space X-ray Telescope Tichý V.; Barbera M.; Collura A.; Hromčík M.; Hudec R.; Inneman A.; Jakůbek J.; Maršík J.; Maršíková V.; Pína L.; Varisco S. Nucl. Instr. Methods A, Vol. 633, Suppl. 1, p. S169-S171, doi:10.1016/j.nima.2010.06.157 2011
The use of contrast agent for imaging biological samples Dammer J.; Weyda F.; Sopko V.; Jakůbek J. JINST 6 C01096, doi: 10.1088/1748-0221/6/01/C01096 2011
Three-dimensional dosimetry imaging of I-125 plaque for eye cancer treatment Weaver M.; Green J.; Petasecca M.; Lerch M.; Cutajar D.; Franklin D.; Jakůbek J.; Carolan M.; Conway M.; Pospíšil S.; Kron T.; Metcalfe P.; Zaider M.; Rosenfeld A. Nucl. Instr. Methods A, Vol. 633, Suppl. 1, p. S276-S278, doi:10.1016/j.nima.2010.06.187 2011
USB Lite-Miniaturized readout interface for Medipix2 detector Vykydal Z.; Jakůbek J. Nucl. Instr. and Meth. A, Volume 633, Supplement 1, Pages: S48-S49, doi: 10.1016/j.nima.2010.06.118 2011
X-Ray Fluorescence Imaging With the Medipix2 Single-Photon Counting Detector Uher J.; Harvey G.; Jakůbek J. IEEE Transactions on Nuclear Science, Vol. PP, Issue: 99, doi: 10.1109/TNS.2011.2173352 2011
X-ray Phase Contrast Imaging Using Single Absorption Coded Aperture Krejčí F.; Jakůbek J.; Kroupa M. Nucl. Instr. Methods A 633, Suppl. 1, 181 - 184 2011
X-ray beam hardening based material recognition in micro-imaging Uher J.; Jakůbek J.; Mayo S.; Stevenson A.; Tickner J. JINST 6 P08015 doi:10.1088/1748-0221/6/08/P08015 2011
X-ray color imaging with 3D sensitive voxel detector Soukup P.; Jakůbek J.; Jandejsek I.; Žemlička J. JINST 6 C12014 doi:10.1088/1748-0221/6/12/C12014 2011
Hard x-ray phase contrast imaging using single absorption grating and hybrid semiconductor pixel detector Krejčí F.; Jakůbek J.; Kroupa M. Rev. Sci. Instrum. 81, 113702 2010
Active Detectors for Plasma Soft X–Ray Detection at PALS Granja C.; Linhart V.; Platkevič M.; Jakůbek J.; Pospíšil S.; Slavíček T.; Krousky E.; Renner O. Acta Polytechnica CTU in Prague, Vol. 50, No. 2 (2010) 12-21 2010
From imaging to dosimetry: GEANT4-based study on the application of Medipix to neutron dosimetry Othman M.; Marinaro D.; Petasecca M.; Guatelli S.; Cutajar D.; Lerch M.; Prokopovich D.; Reinhard M.; Uher J.; Jakůbek J.; Pospíšil S.; Rosenfeld A. Radiation Measurements, Vol. 45, Issue 10, p. 1355-1358 2010
Neutron Dosimeter Development based on Medipix2 Othman M.; Petasecca M.; Guatelli S.; Uher J.; Marinaro D.; Prokopovich D.; Reinhard M.; Lerch M.; Jakůbek J.; Pospíšil S.; Rosenfeld A. IEEE Transactions on Nuclear Science 57 (6): 3456-3462 2010
Vectors and submicron precision: redundancy and 3D stacking in silicon pixel detectors Heijne E.; Ballabriga R.; Boltje D.; Campbell M.; Idarraga J.; Jakůbek J.; Leroy C.; Llopart X.; Tlustos L.; Plackett R.; Pospíšil S.; Tureček D.; Vermeulen J.; Visschers J.; Visser J.; Vykydal Z.; Wong W. Journal of Instrumentation 5 C06004, doi: 10.1088/1748-0221/5/06/C06004 2010
A coated pixel device TimePix with micron spatial resolution for UCN detection Jakůbek J.; Schmidt-Wellenburg P.; Geltenbort P.; Platkevič M.; Plonka-Spehr C.; Šolc J.; Soldner T. NIM A, Vol. 600, Issue 3, p. 651-656 2009
Comparison of Single Photon Counting and Charge-Integrating Detectors for X-ray High Resolution Imaging of Small Biological Objects Frallicciardi P.; Jakůbek J.; Vavřík D. NIM A, Vol. 607, Issue 1, p. 221-222 2009
Detection efficiency of ATLAS-MPX detectors with respect to neutrons Greiffenberg D.; Fiederle M.; Vykydal Z.; Král V.; Jakůbek J.; Holý T.; Pospíšil S.; Maneuski D.; O'Shea V.; Suk M.; Králík M.; Lebel C.; Leroy C. Nucl. Instr. and Meth. A, Volume 607, Issue 1, Pages: 38-40, doi: 10.1016/j.nima.2009.03.103 2009
Energy Sensitive X-ray Radiography and Charge Sharing Effect in Pixelated Detector Jakůbek J. NIM A, Vol. 607, Issue 1, p. 192-195 2009
Energy and Position Sensitive Pixel Detector Timepix for X-Ray Fluorescence Imaging Žemlička J.; Jakůbek J.; Kroupa M.; Tichy V. NIM A, Vol. 607, Issue 1, p. 202-204 2009
Enhancement of spatial resolution of roentgenographic methods Krejčí F.; Jakůbek J.; Dammer J.; Vavřík D. Nucl. Instr. Methods A 607, Issue 1, 208-211 2009
Position-sensitive spectroscopy of ultra-cold neutrons with Timepix pixel detector Jakůbek J.; Platkevič M.; Schmidt-Wellenburg P.; Geltenbort P.; Plonka-Spehr C.; Daum M. NIM A, Vol. 607, Issue 1, p. 45-47 2009
Radiogram enhancement and linearization using the beam hardening correction method Vavřík D.; Jakůbek J. NIM A, Vol. 607, Issue 1, p. 212-214 2009
Real-time in-vivo µ-imaging with Medipix2 Dammer J.; Frallicciardi P.; Jakůbek J.; Jakůbek M.; Pospíšil S.; Prenerová E.; Vavřík D.; Volter L.; Weyda F.; Zemek R. NIM A, Vol. 607, Issue 1, p. 205-207 2009
Pixel 2008 - Invited talk Semiconductor Pixel Detectors and their Applications in Life Sciences Jakůbek J. 2009 JINST 4 P03013 doi:10.1088/1748-0221/4/03/P03013 2009
Study of the charge sharing in silicon pixel detector with heavy ionizing particles interacting with a Medipix2 device Bouchami J.; Gutierrez A.; Houdayer A.; Idarraga J.; Jakůbek J.; Lebel C.; Leroy C.; Martin J.; Platkevič M.; Pospíšil S. NIM A, Vol. 607, Issue 1, p. 196-198 2009
The Medipix2-Based Network for Measurement of Spectral Characteristics and Composition of Radiation in ATLAS Detector Vykydal Z.; Bouchami J.; Campbell M.; Doležal Z.; Fiederle M.; Greiffenberg D.; Gutierrez A.; Heijne E.; Holý T.; Idarraga J.; Jakůbek J.; Král V.; Králík M.; Lebel C.; Leroy C.; Llopart X.; Maneuski D.; Nessi M.; O/'Shea V.; Platkevič M.; Pospíšil S.; Suk M.; Tlustos L.; Vichoudis P.; Visschers J.; Wilhelm I.; Žemlička J. Nucl. Instr. and Meth. A, Volume 607, Issue 1, Pages: 35-37, doi: 10.1016/j.nima.2009.03.104 2009
X-ray polarimetry by means od Compton scattering in the sensor of a hybrid photon counting detector Michel T.; Durst J.; Jakůbek J. NIMA Vol. 603, Issue 3, p. 384-392 2009
Detection of fast neutrons with the Medipix-2 pixel detector Uher J.; Jakůbek J.; Celine L.; Claude L.; Pospíšil S.; Škoda R.; Vykydal Z. Nucl. Instr. and Meth. A, Volume: 591, Issue:1, Pages: 71-74, doi: 10.1016/j.nima.2008.03.027 2008
Energy calibration measurements of MediPix2 Fiederle M.; Greiffenberg D.; Idarraga J.; Jakůbek J.; Král V.; Lebel C.; Leroy C.; Lord G.; Pospíšil S.; Sochor V.; Suk M. NIM A, Vol. 591, Issue 1, p. 75-79 2008
Engineering for the ATLAS SemiConductor Tracker (SCT) end-cap Abdesselam A.; Allport P.; Anderson B.; Beneš P.; Beneš J.; Horažďovský T.; Jakůbek J.; Král V.; Linhart V.; Pospíšil S.; Slavíček T.; Solar M.; Sopko V.; et al. JINST 3 P05002, doi: 10.1088/1748-0221/3/05/P05002 2008
Low-energy nuclear transitions in subrelativistic laser-generated plasmas Renner O.; Juha L.; Krása J.; Granja C.; Jakůbek J.; Linhart V.; Pospíšil S.; Slavíček T.; Vykydal Z. Laser and Particle Beams, Volume: 26, Issue: 2, Pages: 249-257, doi: 10.1017/S0263034608000293 2008
Measuring system for the study of termite control by a juvenogen Tykva R.; Hanus R.; Jakůbek J. Measurement, vol 41, issue 9, p. 1054-1057 2008
Micrometric scale measurement of material structure moving utilizing μ-radiographic technique Vavřík D.; Jakůbek J.; Holý T. NIM A, Vol. 591, Issue 1, p. 24-27 2008
Pattern recognition of tracks induced by individual quanta of ionizing radiation in Medipix2 silicon detector Holý T.; Erik H.; Jakůbek J.; Pospíšil S.; Uher J.; Vykydal Z. Nucl. Instr. and Meth. A, Volume: 591, Issue:1, Pages: 287-290, doi: 10.1016/j.nima.2008.03.074 2008
Pixel Detectors for Imaging with Heavy Charged Particles Jakůbek J.; Cejnarová A.; Holý T.; Pospíšil S.; Uher J.; Vykydal Z. Nucl. Instr. and Meth. A, Volume: 591, Issue:1, Pages: 155-158, doi: 10.1016/j.nima.2008.03.091 2008
Signal processor controlled USB2.0 interface for Medipix2 detector Platkevič M.; Bočarov V.; Jakůbek J.; Pospíšil S.; Tichy V.; Vykydal Z. Nucl. Instr. and Meth. A, Volume: 591, Issue:1, Pages: 245-247, doi: 10.1016/j.nima.2008.03.065 2008
Study of the charge sharing in silicon pixel detector by means of alpha particles interacting with a Medipix2 device Campbell M.; Erik H.; Holý T.; Idarraga J.; Jakůbek J.; Celine L.; Claude L.; Llopart X.; Pospíšil S.; Tlustos L.; Vykydal Z. Nucl. Instr. and Meth. A, Volume: 591, Issue:1, Pages: 38-41, doi: 10.1016/j.nima.2008.03.096 2008
The integration and engineering of the ATLAS SemiConductor Tracker Barrel Abdesselam A.; Allport P.; Beneš P.; Chren D.; Doležal Z.; Holý T.; Horažďovský T.; Jakůbek J.; Kohout Z.; Král V.; Linhart V.; Pospíšil S.; Slavíček T.; Solar M.; Sopko V.; Sopko B.; Štekl I.; et al. JINST 3 P10006 2008
X-Ray Fluorescence Imaging with Pixel Detectors Tichy V.; Holý T.; Jakůbek J.; Linhart V.; Pospíšil S.; Vykydal Z. Nucl. Instr. and Meth. A, Volume: 591, Issue:1, Pages: 67-70, doi: 10.1016/j.nima.2008.03.122 2008
Characterization of 3D thermal neutron semiconductor detectors Uher J.; Jakůbek J.; Kohout Z.; Linhart V.; Pospíšil S.; Fröjd C.; Petersson S.; Kenney C.; Parker S.; Thungstrom G. NIM A 576 (2007) 32-37 2007
Invited contribution.
Awarded by rector of CTU in Prague (2008). Data processing and image reconstruction methods for pixel detectors Jakůbek J. NIM A 576 (2007) 223-234, doi:10.1016/j.nima.2007.01.157 2007
Determination of Iridium Content by Coincidence Neutron Activation Analysis Ndiaye I.; Vobecký M.; Pospíšil S.; Jakůbek J.; Holý T. Chem. Listy 101 (2007) 327-333 2007
Phase contrast enhanced high resolution X-ray imaging and tomography of soft tissue Jakůbek J.; Granja C.; Dammer J.; Tykva R.; Hanus R.; Uher J.; Vykydal Z. Nucl. Instr. and Meth. A, Volume: 571, Issue: 1-2, Pages: 69-72, doi: 10.1016/j.nima.2006.10.031 2007
Position-sensitive spectroscopy of 252Cf fission fragments Granja C.; Jakůbek J.; Pospíšil S.; Vykydal Z.; Kopatch Y.; Telezhnikov S. Nucl. Instr. and Meth. A, Volume: 574, Issue: 3, Pages: 472-478, doi: 10.1016/j.nima.2007.01.164 2007
Small-scale in vivo imaging of soft tissues by radioscopy using single X-ray photon counting Hanus R.; Dammer J.; Holý T.; Jakůbek J.; Pospíšil S.; Tykva R. Journal of Microscopy 226 (2007) 191–194 2007
CdTe Hybrid Pixel Detector for Imaging with Thermal Neutrons Jakůbek J.; Mettivier G.; Montesi M.; Pospíšil S.; Russo P. NIM A Vol. 563, pages 238-241 2006
Data acquisition and processing software package for Medipix-2 device Holý T.; Jakůbek J.; Pospíšil S.; Uher J.; Vavřík D.; Vykydal Z. Nucl. Instr. and Meth. A, Volume: 563, Issue:1, Pages: 254-258, doi: 10.1016/j.nima.2006.01.122 2006
Experimental system for high resolution X-ray transmission radiography Jakůbek J.; Vavřík D.; Holý T.; Jakůbek M.; Vykydal Z. Nucl. Instr. and Meth. A, Volume: 563, Issue 1, Pages: 278-281, doi: 10.1016/j.nima.2006.01.033 2006
Invited contribution to conference VERTEX 2004, Como, Italy Neutron Imaging with MEDIPIX2 Chip and a Coated Sensor Jakůbek J.; Holý T.; Lehmann E.; Pospíšil S.; Uher J.; Vavřík D. NIM A Vol. 560, pages 143-147 2006
Neutron imaging and tomography with Medipix2 and dental microroentgenography Jakůbek J.; Granja C.; Holý T.; Lehmann E.; Linhart V.; Pospíšil S.; Rypar V.; Uher J.; Vacík J.; Vavřík D.; Vykydal Z.; Cevallos M. Nucl. Instr. and Meth. A, Volume: 569, Issue 2, Pages: 205-209, doi: 10.1016/j.nima.2006.08.043 2006
Search for low-energy nuclear transitions in laser-produced plasma Granja C.; Jakůbek J.; Linhart V.; Pospíšil S.; Slavíček T.; Uher J.; Vykydal Z.; Renner O.; et al. Czech Journal of Physics, Volume: 56, Supplement: B, Pages: B478-B484, doi: 10.1007/s10582-006-0241-0 2006
USB Interface for Medipix2 Pixel Device Enabling Energy and Position Detection of Heavy Charged Particles Vykydal Z.; Jakůbek J.; Pospíšil S. Nucl. Instr. and Meth. A, Volume: 563, Issue: 1, Pages: 112-115, doi: 10.1016/j.nima.2006.01.114 2006
Performance of Slow Neutron Pixel Detector Uher J.; Holý T.; Jakůbek J.; Lehmann E.; Pospíšil S.; Vacík J. NIM A Vol. 542, pages 283-287 2005
Quality of X-ray transmission radiography based on single photon counting pixel device Jakůbek J.; Vavřík D.; Pospíšil S.; Uher J. NIM A Vol. 546, pages 113-117 2005
Spatial Resolution of the Medipix-2 as Neutron Pixel Detector Jakůbek J.; Holý T.; Pospíšil S.; Uher J.; Vavřík D. NIM A Vol. 546, pages 164-169 2005
Properties of the single neutron pixel detector based on the Medipix-1 device Jakůbek J.; Holý T.; Pospíšil S.; Uher J.; Vavřík D. NIM A Vol. 531, pages 276-284 2004
Tomography for XRDD Jakůbek J.; Holý T.; Pospíšil S.; Vavřík D. NIM A Vol. 531, pages 307-313 2004
Charge sharing studies with a Medipix1 pixel device Šiňor M.; Jakůbek J.; Linhart V.; Mikulec B.; Pospíšil S.; Sopko B. NIM A Vol. 509, pages 346-354 2003
Resolution and stability tests of a Medipix-1 pixel detector for X-ray dynamic defectoscopy Jakůbek J.; Pospíšil S.; Vavřík D.; Visschers J. NIM A Vol. 509, pages 294-301 2003
LHC1 pixel detector studied in a 120 GeV/c pion test beam Ropotár I.; Jakůbek J.; Pospíšil S.; Štekl I.; et al. NIM A Vol. 493, pages 536-546 2000
Experimental Tests of Neutron Shielding for the ATLAS Forward Region Pospíšil S.; Štekl I.; Čermák P.; Jakůbek J.; Koníček J.; Linhart V.; et al. Nucl. Instr. Meth. in Phys. Res. A 420 (1999) 249-258 1999
Multielement instrumental activation analysis based on gamma-gamma coincidence spectroscopy Vobecký M.; Jakůbek J.; Granja C.; Koníček J.; Pospíšil S. Analytica Chimica Acta 396 (1999) 181-189 1999
Coincidence gamma-gamma spectroscopy system for instrumental neutron activation analysis Jakůbek J.; Pospíšil S.; Štekl I.; Vobecký M.; et al. NIM A Vol. 414, pages 261-264 1998
Search
10th Anniversary of IEAP