Publikace  > Články v impaktovaných časopisech  > 'CT Artefact Reduction by Signal to Thickness Calibration Function Shaping'
CT Artefact Reduction by Signal to Thickness Calibration Function Shaping

Autor

Rok
2011

Časopis
NIM A, Volume 633, Supplement 1, May 2011, Pages S152-S155

Web


Obsah
It is frequently a task to calibrate the radiogram intensity in reference to the object thickness/density value. This knowledge is important when the radiographic densitometry, thickness measurements or precise computed tomography are required. Often aluminum is used as calibrating material and processed radiogram of the real object is evaluated as aluminum equivalent. This approach is qualitatively convenient for transmission radiograms; however, certain secondary artefacts remain in CT reconstructions. Fortunately the calibration function can be shaped using only one or two known thickness values of the object investigated. The shaped calibration function obtained produces the right signal to thickness relationship and CT quality is improved when it is applied.
Granty

Projekty


Příklad citace článku:
D. Vavřík, "CT Artefact Reduction by Signal to Thickness Calibration Function Shaping", NIM A, Volume 633, Supplement 1, May 2011, Pages S152-S155 (2011)